Sanyo MBR-1404G Refrigerator User Manual


 
14
INSTALLATION
Installation
1. Remove the packaging materials and tapes
Remove all transportation packaging materials and
tapes. Open the doors and ventilate the unit. If the
outside panels are dirty, clean them with a neutral
detergent and wipe it up with a wet cloth.
2. Adjust the leveling foot
Extend the leveling feet by rotating them
counterclockwise to contact them to the floor.
See Fig. 1. Ensure the unit is level.
3. Fix the unit
Two hooks are attached to the rear of the cabinet.
Fix the cabinet to the wall with these hooks and rope
or chain.
If holes can be opened on the wall, open a hole with a
10.5 mm diameter and fix the cabinet by using the
special bolt-nut supplied with this cabinet. This
bolt-nut can be used only on concrete walls. See Fig.
2.
4. Ground (earth)
WARNING
Use a power supply outlet with ground (earth) to prevent electric shock. If the power supply outlet is
not grounded, it is necessary to install a ground by qualified engineers.
Never ground the unit through a gas pipe, water main, telephone line or lightning rod. Such
grounding may cause electric shock in the case of an incomplete circuit.
Caster
Leveling foot
Fig. 1
Bolt-nut
45 mm
10.5 mm
Fig. 2