Sanyo MDF-U4186S Freezer User Manual


 
Back cover
Compressors
Front
Rear
Air
Dimensions [Unit : mm (inch)]
Specifications
Model
Temperature range
Maximum cooling
performance
Exterior dimensions
(W x D x H)
Interior dimensions
(W x D x H)
Net weight
Effective capacity
Shelf
Access port
Compressor
Refrigerant
Alarm
Remote alarm
contact
Accessories
MDF-U4186S
–20˚C to –86˚C (1˚C increment)
–86˚C
(Ambient temperature 30˚C)
870 x 780 x 1975 mm
(34.2” x 30.7” x 77.8”)
620 x 515 x 1200 mm
(24.4” x 20.3” x 47.2”)
Approx. 281 kg (619 lbs.)
382 L (13.5 cu.ft.)
Stainless steel, Adjustable,
3 shelves
40 mm diameter,
1 location (left side)
Hermetic type, Output: 1100 W
(high stage side), 1100 W (low
stage side)
HFC refrigerant
High temperature, Power failure,
Filter check, Part replacement
notification
Allowable contact capacity:
DC 30V, 2A
1 set of keys, 1 scraper
Performance Data
Options
Strip chart recorder
MTR-85H
LCO2
backup system
CVK-UB2
LN2
backup system
CVK-UBN2
40
20
0
–20
–40
–60
–80
–100
0
46810
5
12
352520
14
1510
Temperature (˚C)
40
20
0
–20
–40
–60
–80
–100
02
4681012142
Temperature (˚C)
Time (hour)
Time (hour)
Pull-up characteristics
during power failure
30
20
15
10
5
Time (hour)
Ambient temperature (˚C)
CO2 backup system operation
characteristics
Central air temp. in cabinet
Ambient temp. 30˚C, No-load
Inventory rack:
IR-212U
(for 2-inch box)
IR-309U
(for 3-inch box)
Storage rack:
MDF-48SC
(3 drawers)
EVOLUTIONARY DESIGN
• The newly developed refrigeration
system and the freezer structure offer a
quiet experimental environment.
• The newly developed back cover
combined with new aerodynamically
designed and placed components in the
refrigeration compartment provide
superior air flow, making it possible to
drastically reduce the stress to the
freezer and contributing to excellent
durability.
• Two independent and insulated inner
doors prevent cold air leakage.
ACCESSIBILITY
• The condenser filter is
situated at the bottom
right side of the front
panel to make filter
removal and cleaning
easier.
SAFETY
• The backup battery sounds an alarm in
the event of power failure or AC
interruption or abnormality.
• Provides both an audible and visual tem-
perature alarm when the temperature
goes up more than +10°C/+15°C from
the set point.
• Alarm ring back function ensures that
buzzer will resume operation, should
alarm conditions continue after it is
silenced.
• Microprocessor-controlled filter-clog
check function protects the refrigeration
circuit.
• Control panel with digital display for easy
operation.
Pull-down characteristics
*Cooling performance is indicated by the temperature
reached at the center of the freezer (at ambient tempera-
ture of 30°C with no load).
In order to use the freezer at a stable temperature for a long
time, it is recommended that the temperature be set to at
least 5°C higher than the indicated lowest temperature.
In addition, depending on the usage conditions, it may not be
possible to reach the indicated lowest temperature.
Control panel
20 (0.79) 10 (0.39)
1975 (77.8)
1200 (47.2)
870 (34.3)
620 (24.4)
105 (4.13)
30
(1.18)
62
(2.44)
795 (31.3)
780 (30.7)
520 (20.5)
Ambient temp. and maintenance
of –70˚C by injection of LCO
2 (30kg)
IR-212U MDF-48SC
Rack Capacity
IR-212U
IR-309U
MDF-48SC
16
16
8
Distributed by:
©2008 SANYO Printed in Japan 2008.12 MA
SHR143
Features
SANYO Electric Co., Ltd.
Biomedical Division
http://www.sanyo.co.jp/cmg/biomedical
SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for:
Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001
RoHS (European Restriction of Hazardous Substances directives) compliant
MDF-U4186S
• Appearance and specifications are subject to change without notice.
Caution:
SANYO guarantees the product under certain warranty condi-
tions. SANYO in no way shall be responsible for any loss of
content or damage to content.
SANYO DAQ (Data Acquisition) system
MTR-480