Sanyo MDF-U73V Freezer User Manual


 
Dimensions [Unit : mm (inch)]
Performance Data
SAFETY
• Alarm lamp and buzzer offer secure
warning of power failure or abnormal
temperature increase.
• High and low temperature warning
provides an audible and visual alarm
when the temperature deviates more
than ±5˚C to ±20˚C (adjustable) from the
set point.
• Alarm ring-back function ensures that
buzzer will resume operation, should
alarm conditions continue after it is
silenced.
• Microprocessor-controlled filter-clog
check function protects the refrigeration
circuit.
• The rugged, one-handed outer door latch
has a hole to allow a padlock to securely
protect valuable samples.
• Control panel with digital
display for easy opera-
tion.
ACCESSIBILITY
• A beak style inner
door latch tightly
closes the inner door
against the freezer
frame. It also helps make opening and
closing the door smoother.
• The condenser filter is situated at the
bottom right side of the front panel to
make filter removal and cleaning easier.
RELIABILITY
• Status Alert (Condition monitor)
Monitors ambient and system conditions
continuously and notifies of any abnor-
malities before a problem happens.
EVOLUTIONARY DESIGN
• SANYO V.I.P.™ Evolution Series -86˚C
ultra-low temperature freezers use
patented revolutionary vacuum insulation
cabinet construction that reduces the
wall thickness from 14cm to 7cm (5.5”
to 2.7”) and achieves up to 30% more
storage capacity than a conventionally
insulated freezer without increasing the
footprint.
• The newly developed refrigeration
system and the freezer structure offer a
quiet experimental environment.
• Achieves 10% higher energy conserva-
tion than previous model. (For model
rated 220V, 50Hz)
• The newly developed back cover
combined with new aerodynamically
designed and placed components in the
refrigeration compartment provide supe-
rior air flow, making it possible to drasti-
cally reduce the stress on the freezer
and contributing to excellent durability.
• Two independent and insulated inner
doors with gaskets prevent cold air leak-
age.
Back
cover
Compressors
Front
Rear
Air
SpecificationsFeatures
MDF-U73V
•Appearance and specifications are subject to change without notice.
*Cooling performance is indicated by the temperature reached at
the center of the freezer (at ambient temperature of 30°C with no
load). In order to use the freezer at a stable temperature for a long
time, it is recommended that the temperature be set to at least
5°C higher than the indicated lowest temperature.
In addition, depending on the usage conditions, it may not be
possible to reach the indicated lowest temperature.
Caution:
SANYO guarantees the product under certain warranty conditions.
SANYO in no way shall be responsible for any loss of content or
damage to content.
Model
Temperature range
Maximum cooling
performance
Exterior dimensions
(W x D x H)
Interior dimensions
(W x D x H)
Net weight
Effective capacity
Shelves
Access port
Compressor
Refrigerant
Alarm
Remote alarm contact
Accessories
MDF-U73V
–50˚C to –86˚C (1˚C increments)
–86˚C
(Ambient temp. 30˚C)
1010 x 875 x 2010mm
(39.8” x 34.4” x 79.1”)
870 x 600 x 1400mm
(34.2” x 23.6” x 55.1”)
Approx. 350kg (772 lbs.)
728 L (25.7 cu.ft.)
Stainless steel, 3 shelves
17mm diameter, 3 locations
(back, bottom left/right corner)
Hermetic type, Output: 1100 W
(high stage side), 1100 W (low
stage side)
HFC
High/low temperature, Power
failure, Filter check, Self
diagnostics, Door check, Part
replacement nortification
Allowable contact capacity:
DC 30V, 2A
1 set of keys, 1 scraper
Pull-down characteristics
Temperature (˚C)
Time (hour) Time (hour)
Pull-up characteristics during power failure
Time (hour)
Ambient temperature (˚C)
CO2 backup system operation characteristics
Options
Circular recorder
MTR-G85
Strip chart recorder
MTR-85H
Recorder mounting
bracket
MDF-S3085
(for MTR-85H)
LCO2 backup system
CVK-UB2
LN2 backup system
CVK-UBN2
SANYO DAQ (data acquisition) System
MTR-5000/ Ethernet (LAN) Interface MTR-L03
or RS232C/RS485 Interface MTR-480
Inventory rack
IR-220U
IR-224U
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
2
3
4
1
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
2
3
4
1
45
(1.8)
1076 (42.4)
21
(0.8)
1010 (39.8)
870 (34.3)
2010 (79.1)
329
(13.0)
59
(2.3)
450 (17.7) 1560 (61.4)
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
2
3
4
1
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
2
3
4
1
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
2
3
4
1
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
1
4
8
7
2
3
5
6
2
3
4
1
795 (31.3)
600 (23.6)
33 (1.3) 875 (34.4)
105
(4.1)
1400 (55.1)
1
(0.04)
5
(0.2)
5 (0.2)5 (0.2)
672.5 (26.5)672.5 (26.5)
11
(0.4)
1558 (61.3)
1789 (70.4)
28
(1.1)
Temperature (˚C)
40
20
0
–20
–40
–60
–80
–100
02468101214
Central air temp. in cabinet
Ambient temp. 30˚C, No-load
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
0654378921
525201510 30 35
12
10
15
0
Ambient temp. and maintenance
of –70˚C by injection of LCO
2 (30kg)
Distributed by:
©2009 SANYO Printed in Japan 2009.9 MA
SHR148
SANYO Electric Co., Ltd.
Biomedical Division
http://biomedical.sanyo.com/
SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for:
Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001