2. SPECIFICATIONS
2-1. Unit Specifications
Model Number STB0810C1 STB1010C1 STB1020C1 STB1220C1
Voltage (V) 115 115 230 / 208 230 / 208
Performance COOLING
Cooling Capacity BTU/h 8,200 10,200 9,700 / 9,500
11,500 / 11,300
Air Flow....Hi CFM (CMM) 270 (7.65) 270 (7.65) 270 (7.65) 270 (7.65)
Dihumidification Pints/h 2.0 2.7 2.6 3.2
Electrical Rating
Available voltage range V 104 ~ 126 253 ~ 187
Cooling Amperes A 8.3 10.6 5.0 / 5.3 6.1 / 6.6
Watts W 940 1,200 1,140 / 1,110 1,350 / 1,330
Power factor % 98 98 99 / 100 96 / 97
EER BTU/hW 8.7 8.5 8.5 / 8.5 8.5 / 8.5
Starting amperes A 43 53 30 34
Recommeded Circuit Protection A 15 15 15 15
Plug Type
Parallel Parallel Tandem Tandem
Features
Controls / Temperature control Mechanical / Thermostat
Control unit
Timer
Fan speeds 2 2 2 2
Airflow direction (Indoor) Horizontal Manual
Vertical Manual
Air filter Washable
Air exhaust Yes
Compressor Rotary (Hermetic)
R22-Amount charged at shipment OZ 20.1 28.2 23.3 28.2
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Lo dB-A 57 / 55 60 / 57 60 / 57 60 / 57
Outdoor : Hi / Lo dB-A 63 / 60 68 / 64 68 / 64 68 / 64
Dimensions & Weight
Unit dimensions Height In 15-3/4
(Refer to page 7) Width In 25-15/16
Depth In 21-1/2
Package dimensions Height In 18-5/16
Width In 29-1/8
Depth In 24-11/16
Weight Net lbs 82 90 89 93
Shipping lbs 93 101 100 104
Shipping volume Cuft 7.62
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Parallele
115V
15AMP
Tandem
230/208V
15AMP
Perpendicular
230/208V
20AMP
Wall Receptacles
Wall Sleeve Dimension
Remarks: Rating conditions are:
Cooling : Indoor air temperature 80°F D.B. / 67°F W.B. Heating : Indoor air temperature 70°F D.B.
Outdoor air temperature 95°F D.B. / 75°F W.B. Outdoor air temperature 47°F D.B. / 43°F W.B.
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1