Specifications
All Models
208-230/60/1 2 2.6 15
Operating Requirements
MaximumMinimum
Air Temperatures
Water Temperatures
Remote Cond. Temps
Water Pressures
Electrical Voltage
50°F (10°C)
40°F (4.4°C)
-20°F (-29°C)
20 PSIG (1.4 bar)
-10%
100°F (38°C)
100°F (38°C)
120°F (49°C)
80 PSIG (5.5 bar)
+10%
* 208-230/60/1 Voltage - Substitute “-32” in place of “-1”, i.e. C0322SA-32A.
KVS
KSB
KSB-N
Vari-Smart™ Ice Level Control - Program ice bin levels to match ice needs.
Smart-Board™ Advaced Control - Use additional operational data for fast diagnosis.
Smart-Board™ Advanced Control with Network - Network capable.
sm.med.
C0322 on B322 bin. 22” Prodigy plan view.
Dimensions (W x D x H):
Unit:
22” x 24” x 23”
(55.9 x 61.0 x 58.4 cm)
Shipping Carton:
25.5” x 27.5” x 28”
(64.8 x 69.9 x 71.1 cm)
Shipping Weight:
145 lb / 66 kg
BTUs per hour:
5,200
Accessories
Model Number Description
* Scotsman recommends all ice machines have water filtration. See Scotsman Sanitation Matrix for details.
Model Number*
Cube Size: medium or small
Condenser
Unit
Basic Electrical
Volts/Hz/Phase
Max. Fuse Size
or HACR Circuit
Breaker (amps)
Circuit
Wires
Min. Circuit
Ampacity
Energy Consumption
kWh/100 lb (45.4 kg)
90˚F(32˚C)/70˚F(21˚C)
Water Usage
Gallons/100 lb (liters/45.4 kg)
Potable
90˚F(32˚C)/
70˚F(21˚C)
Condenser
90˚F(32˚C)/
70˚F(21˚C)
Ultrasonic
Bin Level
Sensor
(Optional)
7.00”
(17.8 cm)
22.00”
(55.9 cm)
19.05”
(48.4 cm)
24.00”
(61 cm)
Ice Drop Opening
2.00”
(5.1 cm)
2.00”
(5.1 cm)
3.25”
(8.3 cm)
10.25”
(26 cm)
Electrical
Entrance
3/8” FPT
Machine
Water In
3/4” FPT
Machine
Drain
34.00”
(86.4 cm)
MAX.
3/4” FPT
Bin Drain
6.00”
(15.2 cm)
22.00”
(55.9 cm)
3/8” FPT
Condenser
Outlet
WC Units Only
44.00”
(111.8 cm)
3/8” FPT
Condenser
Inlet
WC Units Only
23.00”
(58.4 cm)
24.00”
(61.0 cm)
Intake
Air
Exhaust Air
(AC Units Only)
Installation Note: Allow 6” space at left, back and right side for ventilation and utility connections.
C0322MA-1A
C0322MW-1A
C0322SA-1A
C0322SW-1A
Air
Water
Air
Water
115/60/1
115/60/1
115/60/1
115/60/1
15
15
15
15
2
2
2
2
12.7
11.9
12.7
11.9
6.6
4.7
6.6
4.7
19.0/72.0
18.3/69.4
19.0/72.0
18.3/69.4
-
138.0/523.3
-
138.0/523.3
Specifications and design are subject to change without notice.