Specifications
All Models
* 208-230/60/1 Voltage - Substitute “-32” in place of “-1”, i.e. C0522SA-32A.
KVS
KSB
KSB-N
ERC111-1A
RTE10
RTE25
RTE40
RTE75
Vari-Smart™ Ice Level Control - Program ice bin levels to match ice needs.
Smart-Board™ Advanced Control - Use additional operational data for fast diagnosis.
Smart-Board™ Advanced Control with Network - Network capable.
Remote Condenser for C0522xR, 115/60/1 - Consult Remote Condenser Spec Sheet for details.
Line set, Precharged, R-404A, 10ft.
Line set, Precharged, R-404A, 25ft.
Line set, Precharged, R-404A, 40ft.
Line set, Precharged, R-404A, 75ft.
C0522 on B322 bin. 22” Prodigy plan view.
Dimensions (W x D x H):
Unit:
22” x 24” x 23”
(55.9 x 61.0 x 58.4 cm)
Shipping Carton:
25.5” x 27.5” x 28”
(64.8 x 69.9 x 71.1 cm)
Shipping Weight:
160 lb / 73 kg
BTUs per hour:
7,900
Accessories
Model Number Description
* Scotsman recommends all ice machines have water filtration. See Scotsman Sanitation Matrix for details.
Installation Note: Allow 6” space at left, back and right side for ventilation and utility connections.
sm.med.
Model Number*
Cube Size: medium or small
Condenser
Unit
Basic Electrical
Volts/Hz/Phase
Max. Fuse Size
or HACR Circuit
Breaker (amps)
Circuit
Wires
Min. Circuit
Ampacity
Energy Consumption
kWh/100 lb (45.4 kg)
90˚F(32˚C)/70˚F(21˚C)
Water Usage
Gallons/100 lb (liters/45.4 kg)
Potable
90˚F(32˚C)/
70˚F(21˚C)
Condenser
90˚F(32˚C)/
70˚F(21˚C)
C0522MA-1A
C0522MR-1A
C0522MW-1A
C0522SA-1A
C0522SR-1A
C0522SW-1A
Air
Remote
Water
Air
Remote
Water
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
15
15
15
15
15
15
2
2
2
2
2
2
13.8
14.9
12.2
13.8
14.9
12.2
6.7
6.5
4.4
6.7
6.5
4.4
18.5/70.2
18.2/69.0
18.3/69.4
18.5/70.2
18.2/69.0
18.3/69.4
-
-
142.0/538.4
-
-
142.0/538.4
Electrical
Entrance
3/8” FPT
Machine
Water In
3/4” FPT
Machine
Drain
34.00”
(86.4 cm)
MAX.
Intake
Air
3/4” FPT
Bin Drain
6.00”
(15.2 cm)
22.00”
(55.9 cm)
3/8” FPT
Condenser
Outlet
WC Units Only
44.00”
(111.8 cm)
3/8” FPT
Condenser
Inlet
WC Units Only
23.00”
(58.4 cm)
24.00”
(61.0 cm)
Remote Condenser
Discharge Line
1/2” Male Cplg.
Remote Condenser
Liquid Line
3/8” Male Cplg.
Exhaust Air
(AC Units Only)
Ultrasonic
Bin Level
Sensor
(Optional)
7.00”
(17.8 cm)
22.00”
(55.9 cm)
2.00”
(5.1 cm)
2.00”
(5.1 cm)
3.25”
(8.3 cm)
10.25”
(26 cm)
19.05”
(48.4 cm)
24.00”
(61 cm)
Ice Drop Opening
Operating Requirements
Minimum
Air Temperatures
Water Temperatures
Remote Cond. Temps
Water Pressures
Electrical Voltage
50°F (10°C)
40°F (4.4°C)
-20°F (-29°C)
20 PSIG (1.4 bar)
-10%
100°F (38°C)
100°F (38°C)
120°F (49°C)
80 PSIG (5.5 bar)
+10%
Maximum
Specifications and design are subject to change without notice.