Specifications
All Models
* 208-230/60/3 Voltage - Substitute “-3” in place of “-32”, i.e. C1030SA-3A.
C1030 on B530S bin. 30” Prodigy plan view.
Dimensions (W x D x H):
Unit:
30” x 24” x 29”
(76.2 x 61.0 x 73.7 cm)
Shipping Carton:
33.5” x 27.5” x 34”
(85.1 x 69.9 x 86.4 cm)
Shipping Weight:
235 lb / 107 kg
BTUs per hour:
16,200
Installation Note: Allow 6” space at left, back and right side for ventilation and utility connections.
sm.med.
Model Number*
Cube Size: medium or small
Condenser
Unit
Basic Electrical
Volts/Hz/Phase
Max. Fuse Size
or HACR Circuit
Breaker (amps)
Circuit
Wires
Min. Circuit
Ampacity
Energy Consumption
kWh/100 lb (45.4 kg)
90˚F(32˚C)/70˚F(21˚C)
Water Usage
Gallons/100 lb (liters/45.4 kg)
Potable
90˚F(32˚C)/
70˚F(21˚C)
Condenser
90˚F(32˚C)/
70˚F(21˚C)
C1030MA-32A
C1030MR-32A
C1030MW-32A
C1030SA-32A
C1030SR-32A
C1030SW-32A
Air
Remote
Water
Air
Remote
Water
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
20
20
15
20
20
15
2
2
2
2
2
2
16.0
15.8
14.8
16.0
15.8
14.8
5.0
5.0
4.0
5.0
5.0
4.0
18.4/69.8
18.2/69.0
19.7/74.7
18.4/69.8
18.2/69.0
19.7/74.7
-
-
153.0/580.1
-
-
153.0/580.1
Ultrasonic
Bin Level
Sensor
(Optional)
7.00”
(17.8 cm)
30.00”
(76.2 cm)
2.00”
(5.1 cm)
2.00”
(5.1 cm)
3.25”
(8.3 cm)
10.25”
(26 cm)
19.05”
(48.4 cm)
24.00”
(61 cm)
Ice Drop Opening
Electrical
Entrance
3/8” FPT
Machine
Water In
3/4” FPT
Machine
Drain
34.00”
(86.4 cm)
MAX.
Intake
Air
3/4” FPT
Bin Drain
6.00”
(15.2 cm)
30.00”
(76.2 cm)
3/8” FPT
Condenser
Outlet
WC Units Only
44.00”
(111.8 cm)
29.00”
(73.7 cm)
24.00”
(61.0 cm)
Remote Condenser
Discharge Line
1/2” Male Cplg.
Remote Condenser
Liquid Line
3/8” Male Cplg.
3/8” FPT
Condenser
Inlet
WC Units Only
Exhaust Air
(AC Units Only)
Vari-Smart™ Ice Level Control - Program ice bin levels to match ice needs.
Smart-Board™ Advanced Control - Use additional operational data for fast diagnosis.
Smart-Board™ Advanced Control with Network - Network capable.
Remote Condenser for C1030xR, 208-230/60/1 - Consult Remote Condenser Spec Sheet
Line set, Precharged, R-404A, 10ft.
Line set, Precharged, R-404A, 25ft.
Line set, Precharged, R-404A, 40ft.
Line set, Precharged, R-404A, 75ft.
KVS
KSB
KSB-N
ERC311-32A
RTE10
RTE25
RTE40
RTE75
Accessories
Model Number Description
* Scotsman recommends all ice machines have water filtration. See Scotsman Sanitation Matrix for details.
Operating Requirements
Minimum
Air Temperatures
Water Temperatures
Remote Cond. Temps
Water Pressures
Electrical Voltage
50°F (10°C)
40°F (4.4°C)
-20°F (-29°C)
20 PSIG (1.4 bar)
-5%
100°F (38°C)
100°F (38°C)
120°F (49°C)
80 PSIG (5.5 bar)
+10%
Maximum
for details.