Scotsman Ice Flake and Nugget Ice Machine Ice Maker User Manual


 
FOR THE ELECTRICIAN
CONFORM TO ALL APPLICABLE
CODES
Connect the electrical power to the machine to the
wires in the junction box at the rear of the machine.
Check the nameplate (located on the back panel)
for the voltage requirements, and for the minimum
circuit ampacity. The machine requires a solid
chassis to earth ground wire.
The ice machine should be connected to its own
electrical circuit so it would be individually fused.
Voltage variation must remain within design
limitations, even under starting conditions.
All external wiring must conform to national,
state, and local electrical codes. The use of a
licensed electrician is required to perform the
electrical installation.
NME454, 654 & FME504, 804
January 2007
Page 7
WATER
COOLED
AIR
COOLED
POWER
SUPPLY
FOR THE INSTALLER
Final Check List
1. Is the ice system installed indoors in a location
where the air and water temperatures are
controlled, and where they do not exceed the
design limitations?
2. Is there an electrical service disconnect within
sight of the installed machine? Has the voltage
been checked, and compared to nameplate
requirements?
3. Have all the plumbing connections been made
and checked for leaks?
4. Has the machine and bin been leveled?
5. Is there a minimum of 6" clearance at the back
of the machine for proper service access and air
circulation?
6. Is the water pressure a minimum of 20 PSIG?
7. Has the machine been secured to the bin?
8. Is there clearance over the top of the machine
for service access?
9. Is there a water shut off valve installed near the
machine?
10. Have all of the shipping blocks been removed?