Scotsman Ice FME504 Ice Maker User Manual


 
AUGER MAINTENANCE
In some areas, the water supply to the ice maker
will contain a high concentration of minerals, and
that will result in an evaporator and auger
becoming coated with these minerals, requiring a
more frequent removal than twice per year. If in
doubt about the condition of the evaporator and
auger, the auger can be removed so the parts can
be inspected.
Note: Water filters can filter out suspended solids,
but not dissolved solids. “Soft” water may not be
the complete answer. Check with a water
treatment specialist regarding water treatment.
For more information on removal of these parts,
see REMOVAL AND REPLACEMENT.
1. To remove the auger, remove the front and top
panels.
2. Push bail clamp back from the top of the chute
cover.
3. Unscrew and remove ice sweep.
4. Remove 4 allen screws holding breaker to
evaporator.
5. Pull up to remove auger.
After the auger has been removed, allow the auger
to dry: if the auger is not bright and shiny, it must
be cleaned.
Clean the auger and evaporator as required. DO
NOT HONE THE EVAPORATOR.
7. Replace the water seal.
8. Reverse to reassemble.
NME454, 654 & FME504, 804
January 2007
Page 21
ICE SWEEP
BREAKER
COVER
FME Components
Shown, NME similar.
ALLEN
SCREWS
BREAKER &
BEARING &
AUGER
ASSEMBLY
FME Components
Shown, NME similar.