NME454, 654 & FME504, 804
January 2007
Page 11
Clean the air cooled condenser.
The air flow on this model is from front to back, so
the inside of the machine will have to be available
to clean the air cooled condenser. Use a vacuum
cleaner or coil cleaner if needed. Do NOT use a
wire brush.
A. Disconnect electrical power, and remove the
filter. The filter may be cleaned or replaced.
B. Clean the condenser: the condenser may
appear to be clean on the surface, but it can still be
clogged internally. Check with a flash light from the
front to see if light can be seen though the
condenser fins. Reverse to reassemble.
AIR COOLED MAINTENANCE
Step 1: Remove the top panel.
Step 2: Remove the top portion of the fan shroud.
Step 3: Clean the condenser.
Hazardous Moving
Parts.
Moving fan blade can
cause personal injury.
Disconnect electrical
power before beginning.