Scotsman Ice NME454 Ice Maker User Manual


 
OPERATION: Water
Water enters the machine through the 3/8" male
flare at the rear of the cabinet, goes to the water
reservoir which it enters through the float valve.
The water then goes out the bottom of the
reservoir tank to the bottom of the evaporator.
Reservoir overflow or evaporator condensation is
routed to the drain. Water cooled models have a
separate water circuit for the cooling water: it
enters the fitting at the rear, goes to the water
regulating valve, then to the water cooled
condenser and down the drain.
NME454, 654 & FME504, 804
January 2007
Page 14
Water Level: The correct water level should be
checked when the machine is making ice. Check the
water level in the reservoir and compare it to the
horizontal line molded into the side of the reservoir.
The correct level should be between
1
8
" above and
1
4
"
below the line. If needed, bend the float arm up or
down to adjust the water level.
EVAPORATOR
DRAIN
WATER LEVEL
EVAPORATOR
ICE
CHUTE
DRAIN
WATER SCHEMATIC
RESERVOIR