BK
BK
EARTH GROUND
BU
JUNC TION BOX
USE COPPER CONDUCTORS ONLY
THIS UNIT MUST BE GROUNDED
ALL CONTROLS SHOWN IN
ICE MAK ING MODE
CONT ROL B O X
CIRCUITBOARD
SEE NAMEPLATE
FOR SUPPLY VOLTAGE
AND MAX FUSE SIZE
BK
7-2678-01
(AIR COOLED
ONLY)
V
BU
BK
BU
BU
4
1
S- A1
2
AUGERDRI VE
MOTOR
OL
RUN
START
NC
CENTRIFUGAL
SWITCH
R
MODE SWI TCH
BU
COMP RE SSOR
Y
Y
L2 L1
T2
T1
RUN
CAP
1
25
POTENTIAL
RELAY
START
CAP
H IGH PRESS
CONTROL
BK
R
Y
COND
FAN
3
6
5
2 1
4
V
BK
BK
GN
C
R
S
R
R
BU
BU
CONT A CTOR
CONDUCTIVITY
PROBE
BK
R
BK
BK
R
789
456
123
BIN FULL
EMITTER
(LED)
BINFULL
DETECTOR
PHOTOTRANS
LOW PRES S
CONTR OL
AIR AND WATER COOLED, 208-230/60/1
NME954 & FME1204 SERVICE PARTS
January 2000