Sears 233.52159 Ventilation Hood User Manual


 
PREPARATION
1. Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay
out the range hood's mounting holes, vin'ing access and ductwork
by marking the cabinet bottom and drywall where applicable.
2. Make cutouts for wiring and ductwork.
3. If the hood is to be ducted,install the ductwork so that is flush to
the range hood's mounting surface.
Refer to FIGURE 1 if the range hood is to be installed with a
horizontal discharge.
Refer to FIGURE 2 and FIGURE 3 if the range hood is to be
installed with a vertical discharge.
4. Run two-conductor wire (with ground) from a power source to
the hood location.B(mg approximately 12"of wiring through wir-
ing hole in cabinet.
5. DriU four 3/32" diameter pilot holes at points where mounting
holes are marked in cabinet bottom.
6. Insert four (4) mounting screws, leaving approximately ¼" of
thread exposed.
7. Remove and retain the mounting screws securing the 3¼"x 10"
and 7 _duct transitions to the hood. Install the appropriate duct
transition as described in the installation section.
I N STALLATIO N
1. Remove the necessary duct opening and wiring knockout from
the range hood.
If the range hood is to be installed as a non-ducted unit, re-
move the wiring knockout only.
If the range hood is to be installed as a dueted unit, a baffle
plate is provided to close off the nonMucted vent. InstaB baffle
plate (Refer to FIGURE 4) by sliding into place behind grille. Use
locator bumps to orient in grille.
2. For 7" round discharge installation, refer to FIGURE 5. Secure
7" adapter (included) to top of hood using screws provided, in-
stall 7" round damper (Model BPg7, purchased separately).
For 3V_x 10" vertical _ installation, refer to FIGURE 6. Se-
cure 3¼" x 10" transition (if used) to top of hood.
For 3_i" x 10" horizontal discharge installation, refer to FIG-
URE 7. If using the supplied _10" duct transition, remove the
damper flap from the transition to prevent possible venting inter-
ference. Position transition into wall cutout. Note:The transition
does not fasten to the hood.
3. Feed the wiring through the access hold and into the electrical
box.
4. Align hood's keyhole mounting slots over the four (4) partially
installed screws.
5. Making sure the duct positions over the hood's duct transition,
push the hood against the rear wail. Secure hood by tightening
SCreWS.
6. Using a long blade screwdriver, reach into the discharge opening
and make sure the damper flap operates freely (vertical discharge
only).
LOCATORS
_ BAFFLE PLATE
FIGURE 4
ADAPTER
(Included)
FIGURE 5
SECURE TRANSITION
T WITH SCREWS (Included)
FIGURE 6
POSITION DUCT
TRANSITION iN
WALL CUTOUT
÷,°
HORIZONTAL
FIGUILE7