Sears 75371 Range User Manual


 
A: Usage Situations Where Appliance Power Cord
W'dl Be Disconnected Infrequently.
TEMPORARY METHOD
(Adapter plugs not
permitted in Canada) ---_ _,_
Align large prongs/slots _ !
\ / )t / _-JEnsure proper ground
\ /[ i and firm connection
L_ before use
An adapter may be used only on a 15-amp circuit. Do
nor use an adapter on a 20-amp circuit. Where local
codes permit, a TEMPORARY CONNECTION may
be made to a properly grounded two-prong wall
receptacle by the use of a UL-listed adapter, available
at most hardware stores. The larger slot in the adapter
must be aligned with the larger slot in the wall
receptacle to provide proper polarity in the connection
of the power cord.
CAUTION: Attaching the adapter ground terminal
to the walt receptacle cover screw does not ground
the appliance unless the cover screw is metal, and
not insulated, and the wall receptacle is grounded
through the house wiring. The customer should
have the circuit checked by a qualified electrician
to make sure the receptacle is properly grounded.
When disconnecting the power cord from the adapter,
always hold the adapter with one hand. If this is not
done, the adapter ground terminal is very likely to
break with repeated use. Should this happen, DO
NOT USE the appliance until a proper ground has
again been established.
B: Usage Situations Where Appliance Power Cord
W'dl Be Disconnected Frequently.
Do not use an adapter plug in these situations because
disconnecting of the power cord places undue strain
on the adapter and leads to eventual failure of the
adapter ground terminal. The customer should have
the two-prong wall receptacle replaced with a three-
prong (grounding) receptacle by a qualified electrician
before using the appliance+
The installation of appliances designed for mobile
home installation must conform with the
Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280) or, when such
standard is not applicable, the Standard for
Manufacmied Home Installations, latest edition
(Manufactured Home Sites, Communities and Set-
Ups), ANSI A225.1, latest edition, or with local codes.
In Canada, mobile home installation must be in
accordance with the current CANICSA Z240/MtI
Mobile Home Installation Code.
Electric Disconnect
1. Locate disconnect plug on the range back
2. Pinch sides of connector and ptLUOUtof range back,
Youwill have this disconnect plug:
STEP 4
Seal the Openings
Seal any openings in the wall behind the range and in
the floor under the range when hookups are completed+
(contlm+ednext page)
39