Sharp R-1482 Microwave Oven User Manual


 
12
R-1480
R-1481
R-1482
CK = Check / RE = Replace
POSSIBLE CASE AND 
DEFECTIVE PARTS
PROBLEM
TEST PROCEDURE
CONDITION
OFF
CONDITION
IDLE
CONDITION
MICROWAVE
COOKING
CONDITION
Home fuse blows when power cord is plugged into wall receptacle.
Monitor fuse blows when power cord is plugged into wall receptacle.
Display does not illuminate when power cord is first plugged into wall
receptacle.
Display does not operate properly when STOP/CLEAR key is touched.
(The time of day should appear on the display with beep sound during
normal condition.)
Oven lamp does not light with door is opened.
Hood fan motor operates when power cord is first plugged into wall
receptacle.
Temperature of oven base seems more than 140˚F (60˚C) because of
operation of the range below. But hood fan motor does not turn on
automatically. (Normally, food fan motor should be operating at low
speed.)
Hood lights do not turn on when WORK LIGHT pad or NIGHT LIGHT pad
is pressed.
Hood fan motor does not rotate at all with touched FAN HI/LO pad.
Speed of the hood fan motor does not change when the FAN HI/LO pad is
touched for this function.
Oven lamp does not light in cook cycle. (But it does light when door is
opened.)
Fan motor does not operate. (Oven lamp and turntable motor operate.)
Turntable motor does not operate (Oven lamp lights and fan motor
operate.)
Oven does not go into cook cycle when START pad is touched
Oven seems to be operating but little or no heat is produced in oven load.
(Food incompletely cooked or not cooked at all at end of cook cycle.)
Oven goes into a cook cycle but extremely uneven heating is produced in
oven load (food).
Variable cooking does not operate properly except Cooking Power 10 (P-
HI) mode.
Function of COMPU DEFROST does not operate properly.
Stirrer motor does not operate. (Other parts operate.)
Oven goes into COMPU DEFROST but food is not defrosted well.
CK LOW VOLTAGE
CK NO POWER AT OUTLET
RE SHORTED IN POWER CORD
CK OPENED OR SHORTED WIRING
CK HOOD MOTOR CAPACITOR
RE HOOD LAMP OR SOCKET
CK TURNTABLE OFF CONDITION
RE STIRRER MOTOR
RE TURNTABLE MOTOR
RE FAN MOTOR
RE OVEN LAMP OR SOCKET
P FOIL PATERN ON P.W.B.
O COMPU DEFROST
N RELAY (RY-5)
N RELAY (RY-4)
N RELAY (RY-3)
N RELAY (RY-2)
N RELAY (RY-1)
 M KEY UNIT
L CONTROL UNIT
K HOOD FAN MOTOR 
J HOOD HERMAL CUT-OUT 
I MONITOR FUSE 
H MONITOR SWITCH
G
PRIMARY INTERLOCK SYSTEM
F SECONDARY INTERLOCK SWITCH

E
TEMPERATURE FUSE OR THERMAL CUT-OUT
D HIGH VOLTAGE CAPACITOR
C H.V. RECTIFIER 
B POWER TRANSFORMER
A MAGNETRON