4
R-530EK
R-530EW
ITEM DESCRIPTION
Power Requirements 120 Volts / 13.8 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output 1200 watts (IEC TEST PROCEDURE)
Operating frequency of 2450MHz
Case Dimensions Width 24"
Height 13-3/8"
Depth 19-1/8"
Cooking Cavity Dimensions Width 17-3/8"
Height 10-1/2"
2.0 Cubic Feet Depth 18-5/8"
Control Complement Touch Control System
Clock ( 1:00 - 12:59 )
Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable Cooking
Repetition Rate;
100 PERCENT ............................. Full power throughout the cooking time
90 PERCENT ............................................... approx. 90% of Full Power
80 PERCENT ............................................... approx. 80% of Full Power
70 PERCENT ............................................... approx. 70% of Full Power
60 PERCENT ............................................... approx. 60% of Full Power
50 PERCENT ............................................... approx. 50% of Full Power
40 PERCENT ............................................... approx. 40% of Full Power
30 PERCENT .............................................. approx. 30% of Full Power
20 PERCENT ............................................... approx. 20% of Full Power
10 PERCENT ............................................... approx. 10% of Full Power
0 PERCENT .............................. No power throughout the cooking time
Sensor Cooking pads, Breakfast pad, Lunch pad
15 Minute Recipes pad, Defrost Center pad, From the Pantry pad
Beverage Center pad, Number selection pads, Timer/Clock pad
Keep Warm Plus pad, Minute Plus pad, Power Level pad
Stop/Clear pad, Start/Touch On pad
Oven Cavity Light Yes
Safety Standard UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
SPECIFICATION
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed
and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements
The electrical requirements are a 120 volt 60 Hz, AC only, 15 or 20 amp. fused electrical supply. It is recommended that a
separate circuit serving only this appliance be provided. When installing this appliance, observe all applicable codes and
ordinances.
A short power-supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord.