Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at HIGH 100%.
A
Does the oven light come on? YES _______ NO _______
B
Does the cooling fan work? YES _______ NO _______
(Put your hand over the rear ventilating openings.)
C
Does the turntable rotate? YES _______ NO _______
(It is normal for the turntable to turn in either direction.)
D
Is the water in the oven warm? YES _______ NO _______
If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or
circuit breaker. If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHO-
RIZED SERVICER.
A microwave oven should never be serviced by a “do-it-yourself” repair person.
NOTE:
1. If time appearing in the display is counting down very rapidly, check Demonstration Mode
on page 13 and cancel.
2. If the oven is set for more than 20 minutes at 80, 90 or 100 percent power level, after the
first 20 minutes the power level will automatically adjust itself to 70 percent power to
avoid overcooking.
SPECIFICATIONS
Single phase 120V, 60Hz, AC only
1100W 9.6A
700W
(IEC Test Procedure)
2450 MHz
18
1
/
8
(W) x 10
7
/
8
(H) x 13
7
/
8
(D)
12
5
/
8
(W) x 7
7
/
8
(H) x 13
1
/
4
(D)
Turntable system, 10
3
/
4
diameter
Approx. 24 lb
SERVICE CALL CHECK
AC Line Voltage:
AC Power Required:
Output Power:
Microwave
Frequency:
Outside Dimensions:
Cavity Dimensions
★★
:
Cooking Uniformity:
Weight:
The International Electrotechnical Commissions standardized method for measuring output
wattage. This test method is widely recognized.
★★ Internal capacity is calculated by measuring maximum width, depth and height. Actual
capacity for holding food is less.
In compliance with standards set by:
FCC Federal Communications Commission Authorized.
DHHS Complies with Department of Health and Human Services (DHHS) rule, CFR, Title
21, Chapter I, Subchapter J.
This symbol on the nameplate means the product is listed by Underwriters
Laboratories, Inc.
SEC R201/203/205/206FW,P13-16 03.6.5, 10:46 PM15