Sirius Range Hoods SU900 Ventilation Hood User Manual


 
3
Figure 5
2
6
.
5
2
7
.
6
Figure 4
1
9
.
4
2
0
.
5
Figure 3
For the 20.5” model, the cut out should
19.4” x 10.3”.
For the 27.6” model, the cut out
should be 26.5” x 10.3”.
Sch 31A
The SUT900 has pressure springs on
the front and back that will “hook” onto
the top surface of the underside of the
hood when it is pushed up into the
hole that has been cut out (refer to
figure 6)
Figure 6
I N S T A L L A T I O N
Applications
The SUT900 can either be installed
inside a wall cabinet (provided the
inside depth is greater than 11”) or
used in a custom designed wooden
hood. Where installed directly into a
wall cabinet, there are two options:
Directly into the cabinet without any
form of hood. Directly into the
cabinet together with Sch31A where
the Sch31A acts as a liner hood and
is attached to either the underside of
the cabinet or into the sides of the
cabinets alongside.
Depending on which model is used,
prepare a cut-out in the underside of
the wooden hood to allow the
SUT900 to fit up into the hood (refer
to figure 3 or 4). If Sch31A is being
used, it can be held up under the
cabinet and used as a template.
Remember to make the depth 10.3”.
Please ensure that the SUT900 is
installed as far forward in the wooden
hood as possible and centered over
the cooking area.
If Sch31A is to be used for under
cabinet application, it should be
installed now. Screw Sch 31A to the
4 hole locations. Make sure it lines up
with the cut out in your cabinet (refer
to figure 5).