Smeg A2-6 Range User Manual


 
Instructions for the installer
44
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.05 50 30 400 76 75
Semi rapid
1.8 65 33 500 131 129
Rapid
3 85 45 800 218 215
Triple crown
4.0 100 65 1600 290 286
Burner
Rated heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle
diameter
1/100 mm
Reduced
flowrate
(W)
Auxiliary
1.05 72 400
Semi rapid
1.8 97 500
Rapid
3 115 800
Triple crown
4.0 135 1600
3.3 Arrangement of burners on cooking hob
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra rapid
5 Ultra rapid