Smeg A31X-6 Oven User Manual


 
Instructions for the Installer
12
3. ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, switch off the
power supply to the appliance.
The cooking hob of the cooker is preset for natural gas at a pressure of
1.0 kPa. In the case of functioning with other types of gas the burner
nozzles must be changed and the minimum flame adjusted on the gas
taps. Replace the burner nozzles as indicated in the table of the gas to be
used.
Changing nozzles 3.1
1. Extract the grids and remove all the caps and flame-spreader
crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. proceed with replacing the burner nozzles in accordance with the
table for the gas in question.