Smeg A41A Cooktop User Manual


 
Instructions for the installer
39
2.1 Electrical connection
Check that the voltage and dimensioning of the supply line correspond to
the characteristics shown on the plate fixed to the rear protective cover
of the appliance.
This plate must never be removed.
If the appliance is hooked-up to the supply by means of a fixed
connection, install a multipolar cut-out device on the line, with contact
opening distance equal to or greater than 3mm, located near the
appliance and in an easily reachable position.
Hook-up to the supply may be fixed or with plug and socket. In the latter
case the plug and socket must be suitable for the cable employed and
conform with the regulations in force. Regardless of the type of
connection, earthing of the appliance is absolutely obligatory. Before
connection make sure that the supply line is suitably earthed. Avoid the
use of reducers, adapters or shunts.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.
Single oven model
If the power cable is replaced, the wire
section on the new cable must not be
less than 1.5 mm
2
(3 x 1.5 cable),
keeping in mind that the end to be
connected to the hob must have the
ground wire (yellow-
g
reen) longer by
at least 20 mm. Use only the special
cables available at our Service
Centres.