Smeg AP64S3 Range User Manual


 
Instructions for the installer
32
5 ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the
appliance from the electrical socket.
The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. For functioning with other types of gas the nozzles must be
replaced and the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove
the top as described in the following paragraph.
5.1 Removing the separable control panel (models with
separable control panel)
1. Remove the knobs and the knob guard
tube “A” by pulling them up;
2. Use a crosshead screwdriver to remove
the screws and the two cylindrical
supports “B”;
3. Raise the left-hand side of the control
panel slightly and shift it to the right to
remove it completely;
4. In models with electric hotplate, the body
of the pilot light has to be removed to free
the control panel;
5.2 Removing the hob (models with integrated control
panel)
1. Remove the knobs, the
griddles, the burner caps, the
flame caps and the two rear
plugs;
2. Remove the screws “A
which fix the burner supports;
3. Raise the hob, sliding it off
the ignition plugs and/or the
thermocouples and the gas
tap rods;