Smeg AP91VJME Range User Manual


 
Instruction for the installer
10
3.2 Burner and nozzle characteristics table (60 cm models)
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.0 50 30 350 73 71
Semi-rapid
1.75 65 33 450 127 125
Rapid (3)
3.0 85 45 800 218 214
Rapid (5)
2.3 75 45 800 167 164
Triple crown
3.2 91 65 1500 233 229
Oven
3.2 87 48 850 233 229
Grill
2.9 87 // // 218 214
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced Flowrate
(W)
Auxiliary
1.0 72 350
Semi-rapid
1.75 97 450
Rapid (3)
3.0 115 800
Rapid (5)
2.3 103 800
Triple crown
3.5 133 1500
Oven
3.2 130 850
Grill
2.9 130 //