14
Instructions for the Installer
ADJUSTING THE BURNER MINIMUM SETTING
CONVERTING FROM LPG TO NATURAL GAS
Perform the operations described below on all the gas
taps.
1 Pull off the knob.
2 Make sure that the by-pass inside is screwed fully
down. Use a screwdriver inside or on the side of
the rod (see right).
3 Turn the bypass as stated in the BURNER
CHARACTERISTICS, NOZZLES AND GAS
CONSUMPTION table (see page 10).
4 When adjustments are complete, fit the knob, light
the relative burner and turn it to the minimum
setting . The flame should be even at the
minimum setting.
5 Check that the flame remains stable when the
knob is turned quickly from the maximum to the
minimum setting. The flame must not go out.
6 If the minimum flame is not even, remove the knob
and make small clockwise or anti-clockwise
adjustments to the bypass then check stability
again. Otherwise the minimum flame has been
adjusted successfully.
CONVERTING FROM NATURAL GAS TO LPG.
Perform the operations described below on all the gas
taps.
1 Pull off the knob.
2 Turn the by-pass inside, screwing it fully down.
Use a screwdriver inside or on the side of the rod
(see right).
3 For the grill tap, after screwing the bypass fully
down back it off by 1+1/4 turn.