Smeg CC92MFX6 Range User Manual


 
Instructions for the installer
21
15.FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.
Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the
appliance with the one corresponding to the new gas. This label is in the packet together with the
nozzles.
15.1 Regulation of the hob burner minimum level for natural gas
Light the burner and turn it to the minimum position .
Remove the knob and turn the regulation screw inside or next to the gas tap pin
(depending on the model) until you get a suitable minimum flame. Replace the
knob and check burner flame stability: (rapidly turning the knob from maximum to
minimum position, the flame should not go out). Repeat the operation on all the
gas taps.
For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to
activate the safety device.
15.2 Regulation of the hob burner minimum level for LPG
In order to adjust the minimum with LPG, the screw at the side of the tap rod must be turned clockwise
all the way.
The bypass diameters for each individual burner are shown in paragraph “14.2 Burner and nozzle
characteristics table". Once the regulation has been completed, restore the seal on the by-passes using
paint or similar materials.
15.3 Mounting the rear top skirtboard (where applicable)
• Loosen nuts B.
Position the skirt above the top, taking care to align pins C with
holes D.
Secure the skirt to the top by tightening screws A.
15.4 Wall fixing
Stretch out the chain attached to the cooker horizontally so that
the other end touches the wall.
Mark the wall in the position where the hole is to be drilled.
Drill the hole, insert a wall plug and attach the chain.
Move the cooker up against the wall.