Smeg CIR900X Cooktop User Manual


 
16
Instructions for the Installer
9.1 Electrical connection
Check that the power supply voltage and size are as specified on the
nameplate below the appliance carter.
The nameplate must never be removed.
The appliance must be connected to earth in compliance with electrical
system safety regulations.
If a permanent connection is used, the appliance's power supply line must
be fitted with an omnipolar breaking device with contact gap of at least
3mm, located in an easily accessible position close to the appliance itself.
If a socket and plug connection is used, check that they are of the same
type. Do not use reducers, adapters or junctions since they may cause
overheating or burns.
Operation at 220-240 V~: use a
type H05V2V2-F three-wire cable
(cable of 3 x 0.75 mm
2
)
The earth wire (yellow-green) must
be at least 20 mm longer than the
other wires at the end for connection
to the appliance.
The manufacturer declines all responsibility for injury or damage
caused by failure to comply with the above regulations or deriving from
tampering with even just one part of the appliance.