Smeg CW350B Dishwasher User Manual


 
8
3 DISPLAY
Can indicate the program which will begin and the boiler/Tank
temperature.
In case of anomalies an error code will be indicated, for example
“E 1”
- Boiler temperature anomaly
- Tank temperature anomaly
- Tank loading anomaly
- Tank draining anomaly
- Boiler anomaly
Start button Initiates the program shown on the display
L3
Bicolor led indictor
This led indicates the state of the machine
Green indicates the machine is ready for a new program
Red indicates the machine is busy with an operation
Yellow indicates a break after Tank draining
MACHINE CONFIGURATION PARAMETERS (Intended for technical personnel, not the user
)
Parameter Description Range Preset
P0 Drain cycle time 1-5’ 1
P1 Boiler temperature 60-95°C 82
P2 Tank temperature 40-65°C 55
P3 Rinse duration 10-40’’ 13
P4 BOILER STOP option YES/NO 1 YES
P5 Brief wash time 60-90 60
P6 Drain with overflow option YES/NO 1 YES
P7 Cold rinse option YES/NO 0 NO
P8 Regeneration option YES/NO 1 YES
P9 Maximum water load duration 1-10’ 10
P10 H2O Hardness (to be set by the user based on water hardness) 35 15
P11 Machine type 4 4
P12 Wash number counter YES 1 YES
PARAMETER FUNCTION WITH MACHINE ON
Upon first installation it is possible to perform a series of operations which allow for the personalization of the
dishwasher based on the user’s necessities, as well as a test cycle which quickly checks the functionality of all of
the components. To perform these operations it is necessary to set the machine to “programming mode” as
described hereafter
Shut the machine off by pressing
Simultaneously press
and until P0 appears on the display
With the
button (ahead) and the button (back) select the programs
Once the parameter to modify has been identified, keep the
button pressed and modify the required
setting with the “ahead”
and “back” buttons
Once the setting has been correctly modified, release the
button
When finished with the settings turn the machine off and on again by pressing
Note: always turn on the DRAIN PUMP function in machines with Air Tank or Break Tank even if absent.
IN PARAMETERIZATION MODE, IF NO BUTTON IS PRESSED WITHIN 30 SECONDS THE KEYBOARD SHUTS
DOWN AND RETURNS TO ITS OFF STATE.