5 FIRST STARTUP
FIRST STARTUP
The electrical protection system must be subjected to a functional test before use. The installation must be
performed and/or verified by the authorized reseller who will be responsible for the first startup and the
instructions relative to the dishwasher’s operation.
PREPARATION FOR USE
Important:
The rinse-aid metering unit comes equipped in all models
while the detergent metering unit comes equipped in only
some models.
If both metering units are present position the external
detergent and rinse-aid containers and insert their
respective suction tubes located at the back of the machine.
Red tube: detergent
Transparent tube: rinse-aid
Before inserting the tubes in the containers apply the weight
(necessary to keep the tube at the bottom of the container)
and the filter as indicated in the diagram.
For adjustments, use the adjustment screws indicated in the diagram. It is
recommended that adjustments be performed by personnel from the companies who
have supplied the detergent products.
If the detergent metering unit did not come pre-installed it can be installed at a later
time by ordering the relative KIT.
Alternatively, an external metering unit can be connected by means of an electrical
connection with a 2x0.5 mm type H05 RN-F cable. This cable must be inserted through
the passage indicated in the TECHNICAL CHARACTERISTICS scheme and
connected in accordance with the electrical scheme furnished with the dishwasher.
The metering unit must be of 230V/50Hz with a maximum absorbed power of 15W.
Connect the detergent metering unit to the dishwasher through the red tube cited above.
6 SETTINGS (only models CW400RSD - CW400R – CWC500R)
POWER SUPPLY: 200 – 250 VAC.
ABSORBED POWER : 4 VA
OPERATIONAL TEMPERATURE: 0 / 60 °C
OPERATIONAL HUMIDITY: max 90 % without condensation
NORMS: The control unit is designed and manufactured in observance of the
European norms in vigor regarding electrical safety and electromagnetic compatibility.
Particularly the following:
EN 61000-6-3 : Emissions for residential and commercial environments
EN 61000-6-2 : Immunity for industrial environments
EN 61000-4-11 : Immunity to supply micro-interruptions
EN 60335-1 : Low voltage safety directive
back of the machine.
The protection conductor (PE) is yellow-green in color, the neutral conductor (N) is blue and the
phase conductors (L1, L2, L3) are black, gray and brown.
SETTINGS
During the first startup, arrange for the setup or the adjustment of the functions/parameters indicated
hereafter: