3 Installation and positioning
INSTALLATION and POSITIONING
Bring the dishwasher to its installation location, remove its packaging and verify the integrity of the apparatus
and of the components. If damaged, written notification must be sent to the transporter.
The packaging elements (plastic bags, polystyrene foam, nails, etc) must not be left within reach of children
and domestic animals as they are a potential source of danger.
All of the materials used for packaging are compatible with the environment. They may be safely preserved, or
may be disposed of at an appropriate waste disposal facility.
The components in plastic material subject to eventual disposal through recycling are marked in the following
manner:
PE polyethylene: external wrapping, instructions bag, protection bags.
PP polypropylene: bands.
PS polystyrene foam: protective corners, packaging cover.
The wood and cardboard components can be disposed of by respecting the norms in vigor.
When disposing of the product, avoid leaving it in the environment; its disposal must respect the norms in vigor.
All of the metallic parts are in stainless steel and are detachable.
The plastic parts are marked with the symbol of the relative material.
POSITIONING:
4 INSTALLER – TECHNICAL ASSISTANT
INSTRUCTIONS
Water and drain connection:
The water tubes and the electrical power cable stick out from the back of the machine. Connect the water
supply tube to a ¾” threaded gas outlet.
Use only new tubes for the connection to the water supply; old or used tubes must not be utilized.
The dynamic supply pressure must be between 2 and 4 bar; if the pressure is higher, a pressure reducer
must be installed.
It is indispensable to install a general faucet on the supply water input tubing; the faucet must be accessible
after installation has been completed. Do not install the faucet behind the dishwasher.
The declared cycle durations refer to a 50° hot water supply.
Where a cold water supply is used, the duration of the cycle could increase in relation to the input water
temperature since the dishwasher is equipped with a constant temperature and pressure rinse system.
Drain:
Every dishwasher comes equipped with a drain connection tube; this is prescribed to be at floor level, with a
trap drain.
Caution: make sure that the supply and drain tubes are not bent, restricted or crushed after
installation.
Warning:
the internal system and the locations in which communal apparatus are to be installed,
must answer to the norms in vigor.
The manufacturer declines any responsibility for direct damages to persons of things deriving from lack of
respect for the said norms.
Prior to installation verify that objects and materials which could be damaged by aqueous vapor or by spray
from washing solutions are not in the vicinity, or are adequately protected.
Position the dishwasher in the desired position and remove the protective wrapping.
Level the dishwasher (with the help of a level) on its four feet, regulating them in such a way so as to
guarantee stability; any alternate solution must be approved by the manufacturer.