Smeg ER12550NL Cooktop User Manual


 
Instructions for the installer
23
4. GAS CONNECTION
Connection to the gas mains may be made with a rigid copper pipe or
with a flexible pipe and conforming to the provisions defined by standard
regulations in force.
To facilitate connection, fitting A on the rear of the appliance may be
adjusted laterally. For this purpose, undo the hexagonal nut B, turn the
union A into the position required and retighten the hexagonal nut B to a
torque of at least 20 Nm. An annealed aluminium gasket provides the
seal.
If the gasket is removed it may NOT be reused and must be
replaced with another of exactly the same type.
Use a soapy solution to check for proper tightness. Never use a free
flame.
The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. For use with other types of gases, see Section “5.
ADAPTATION TO DIFFERENT TYPES OF GAS”. The gas intake fitting
is ½” gas external tapered thread (ISO 7-1).
Always place a suitable sealing medium (such as Teflon tape) between
union A and pipe C/D.
Connection with rigid copper pipe:
the connection to the gas mains must
not provoke stress of any kind on the
hob.
Connection may be made by using
biconical adapter D.
Connection with flexible pipe: use
only flexible pipes conforming to
standard regulations in force.
The flexible pipe has to be installed so that pipe length does not exceed
1.5 meters of maximum extension. Make sure that the pipes do not touch
any moving parts or become damaged.