Smeg GKC64-3 Cooktop User Manual


 
Instructions for the installer
32
following the instructions given in the tables for bottled gas G30/G31 –
28/37 mbar. The nozzle must not be tightened to a torque of over 3
Nm. Regulate the air flow by moving the Venturi pipe “C”, until the gap
A” is as shown in the table in point “
5.5 Regulation of primary air” and
fix it with the screw “D”. After making the adjustments, restore the
seals with sealing wax or an equivalent material.
Burner
Rated
heating
LPG – G30/G31 28/37 mbar
capacity
Nozzle
Diameter
1/100
mm
By-pass
1/100 mm
[V
(1)
]
By-pass
1/100 mm
[NV
(1)
]
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.05 48 30 30 400 76 75
Semi-rapid
1.7 62 32 32 450 124 121
Rapid
2.55 76 42 42 750 185 182
Rapid large
3.1 85 42 42 750 225 222
Fish pan
2.9 82 48 50 950 211 207
Ultra rapid
4.0 95 63 65 1600 291 286
(1)
V = Valved; NV = Nonvalved