Smeg GKC755 Cooktop User Manual


 
Instructions for the installer
31
5.3 Regulation for natural gas
The hob has been inspected for G25 (2L 3B/P) at a pressure of 25
mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax o
r
equivalent material.
Burner
Rated
heating
capacity
G25 25 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.05 76 380
Semirapid 1.65 98 380
Rapid 2.7 123 650
Rapid large 3.1 130 750
Fish pan 2.15 110 750
Ultra rapid 3.3 135 1200
Internal 1.05 76 380
Double
crown
External 3.9 150 1200