2.3 Connecting to natural and LPG gas
(Please see connection diagram)
Make the connection to the appliance using flexible bayonet style hose in
accordance to B.S. 669. The hose connection at the rear of the appliance has a ½”
BSP internal thread. Please use seal C between the flexible connection L and the
appliance supply tube B. When making the connection, make sure that no stress of
any kind is applied to the cooker and that the hose does not touch any sharp
edges.
If connecting to LPG the bayonet hose must have red bands on it.
2.3.1 Connection to the gas bottle inside the compartment in the cooker (on some models
only)
Open the side door and put in a gas bottle (max. 15
kg). Fit one end of the pipe to the pipe holder and fix it
to one of the clamps supplied. Insert the pipe into the
bottle compartment through the hole in the back of the
cooker as shown in the diagram here. Fit the free end
of the pipe to the pressure regulator on the gas bottle:
fix it with the second clamp. Check for any leaks
using a soapy solution, never with a live flame.
To connect the cooker to a gas bottle, use a piece of regulation rubber pipe 1.4 m (
±
0.05 m) long