Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 120 mm.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 120 mm in the wall unit over the
hood.
• Connect the hood body outlet to the top part of
the wall unit using a rigid or flexible pipe ø 120
mm, to be selected by the installer.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Ensure that the activated charcoal filters have
been inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
• When opening the sliding carriage for the first time after installing the hood, pull it out briskly
until it clicks.