Smeg KSEG5X Ventilation Hood User Manual


 
EN
1
13
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120 mm, the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
Remove possible charcoal filters.
ø 150
9
ø 120
RECIRCULATION VERSION AIR OUTLET
Connect the flange to the outlet on the shelf over the
hood using a flexible or rigid pipe (ø120 or 150 mm).
To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Ensure that the activated charcoal filters have been
inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm..