Instructions for the installer
35
6.2 Fitted installation (module only)
MEASUREMENTS FOR FITTED INSTALLATION
MODEL
MATERIAL HEIGHT MC30RA
NOT COMBUSTIBLE
A 310 mm
B 150 mm
COMBUSTIBLE
A 320 mm
B 200 mm
A rubber cap is supplied (A) that must be removed if the appliance
is installed on a trolley as illustrated in the figure to the side.
If the product is embedded in a masonry compartment do not
remove the cap or provide an appropriate means for the outlet.
FRONT CROSS-SECTION
VIEW
SIDE CROSS-SECTION
VIEW
DISTANCE IF
SIDE WALL PRESENT
HOLE FOR REAR
GAS CONNECTION
POSSIBLE BOTTOM COMPARTMENT
DISTANCE IF REAR
WALL PRESENT
HOLE FOR GAS
CONNECTION IN
PRESENCE OF REAR
WALL
HOLE FOR REAR
GAS CONNECTION
A