Smeg PGFA95F Cooktop User Manual


 
Instructions for the installer
2.2 Attachment to support structure, flush-mounting model
Create an opening with the dimensions
shown in the figure in the work surface,
observing a minimum distance of 50 mm
from the rear edge.
The lower part of the protective cover
must be fully accessible when the
appliance is installed. This appliance can
be installed next to walls that are higher
than the work surface, as long as the
distance "X" is kept, as shown in the
figure, to avoid damage from overheating.
1)
Make sure there is a minimum of 750 mm (Fig. 1) between the gas rings and any shelf
that may be installed directly above them. This type of appliance requires the worktop,
the dimensions of which are shown shown in figure 2, to be milled to a depth of 2.5
mm. Before positioning the hob, position the adhesive sponge material “E” supplied
over the milled surface (fig. 3). Having done this, place the hob on the milled surface
and using the screws and fixing brackets “C” or “D” (depending on the depth of the
worktop) secure the hob to the support structure, ensuring it is level. The brackets
C” secure the hob to a structure having a depth of 20 to 30 mm. The brackets “D” on
the other hand, are for use with worktops having a depth of 30 to 50 mm.
2)
3)
4)
Mill to this depth for laminated worktops of less
than 3mm thickness.
Apply a layer of “waterproof primer” to the milled surface.
Important: Other types of installation will only be possible under th
e
manufacturer's supervision.