Smeg PGFA95F-1 Range User Manual


 
Instructions for the installer
2.2 Fixing the flush-top model to the structure.
Create an opening with the dimensions
shown in the figure in the work surface,
observing a minimum distance of 50 mm
from the rear edge.
The lower part of the protective cover must
be fully accessible when the appliance is
installed. This appliance can be installed
next to walls that are higher than the
1)
the work surface, as long as the distance "X" is kept, as shown in the figure, to avoid
damage from overheating. Make sure there is a minimum of 750 mm (Fig. 1) between
the gas rings and any shelf that may be installed directly above them.
This type of appliance requires the worktop, the
dimensions of which are shown shown in figure
2, to be milled to a depth of 2.5 mm. Before
positioning the hob, position the adhesive
sponge material “E” supplied over the milled
surface (fig. 3). Having done this, place the hob
on the milled surface and using the screws and
fixing brackets “C” or “D” (depending on the
depth of the worktop) secure the hob to the
2)
support structure, ensuring, ensuring it is level.
The brackets “C” secure the hob to a structure
having a depth of 20 to 30 mm. The brackets
D” on the other hand, are for use with worktops
having a depth of 30 to 50 mm.
3)
Apply a layer of “waterproof primer” to the milled surface.
8