Instructions for the installer
19
9. INSTALLING THE APPLIANCE
The hotplate must be installed on a horizontal worksurface, and must be freestanding. The distance from
the rear wall must allow easy access to the terminal board in order to allow connection of the power
supply cable.
Installation must be carried out by a qualified technician and in accordance with current EEC regulations.
9.1 Technical specifications data plate
Make sure that the voltage and capacity of the power
supply cable conform to the data shown on the plate
located under the protective cover. Do not remove this
plate for any reason.
9.2 Electrical connection
Regulations require that the appliance is earthed in accordance with electrical safety regulations.
Make sure that the voltage and capacity of the power supply cable conform to the data shown on the
plate located on the rear of the appliance. Do not remove this plate for any reason.
The hotplate comes supplied with a 3-pole H07RN-F cable for use at 220-240V~ and with a power plug.
The cable provided is 3-pole 3 x 1.5 mm
2
type H07RN-F.
In order to avoid any risks, have the power cable replaced if necessary by a qualified electrician only.
Ifusing a permanent connection, install an all-pole disconnect switch on the line with a minimum contact
gap of 3 mm, located at an easily accessible position near the appliance.
Ifusing a power plug and socket connection, ensure these are of the same type. Do not use reducers,
adapters or shunts since they could caused overheating or burns.
9.2.1 Safety thermostat
The appliance is equipped with a safety device that trips in the event of serious malfunction. To reset the
safety device, contact the after-sales technical service.
The manufacturer declines all liability for injury to persons or animals and for damage to property
resulting from non-observance of the above prescriptions or from tampering with any part of the
appliance.