ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.
Chimney assembly
Upper exhaust Chimney
Slightly widen the two sides of the upper chimney and hook
them behind the brackets 7.2.1 using the 2 screws 12c
Lower exhaust Chimney
Slightly widen the two sides of the flue and hook them be-
tween the upper flue and the wall, making sure that they are
well seated.
• Remove the filters one at a time, supporting them with one
hand and turning the safety knobs (pull and turn) and fix the
lower part to the hood body from under using the 4 screws 12c
supplied.
12c
2.2
2.1
2
12c