Smeg SC04MFX Oven User Manual


 
33
Instructions for the installer
Operation at 220-240 V~: use a
H05RR-F / H05RN-F three-wire cable
(cable of 3 x 4 mm
2
).
Operation at 380-415V2N~: use a type
H05RR-F / H05RN-F four-wire cable
(cable of 4 x 2.5 mm
2
).
Operation at 380-415V3N~: use a type
H05RR-F / H05RN-F five-wire cable
(cable of 5 x 1.5 mm
2
).
The earth wire (yellow-green) must be at
least 20 mm longer than the other wires
at the end for connection to the
appliance.
14.2 Positioning the oven
The appliance is designed for building-in to cabinets made from any heat-
resistant material. Comply with the dimensions shown in figures 1, 2, and
3. When installing under worktops, comply with the dimensions shown in
figure 1-3. When installing under worktops incorporating combined hobs, a
gap of at least 110 mm must be left from any side wall, as shown in figure
1. When installing in tall units, comply with the dimensions shown in figure
1-2, bearing in mind that the top/rear of the unit must have an opening 80-
90 mm deep. Screw the 4 screws A into the inside of the frame (fig. 1). For
installation under counter-top hobs, make sure that the rear/bottom of the
unit has an opening similar to that shown in figure 1 (ref. B). See the
instructions supplied with the hob for the relative positioning and fixing
procedures.