Smeg SCDK380X Oven User Manual


 
27
Instructions for the installer
13. INSTALLING THE APPLIANCE
13.1 Electrical connection
The I.D. plate with technical data, serial number and brand name is
positioned visibly on the oven door frame.
The plate must not be removed.
The appliance must be connected to earth in compliance with electrical
system safety regulations.
If a fixed connection is being used, fit the power line with an omnipolar
circuit breaker with a contact opening gap equal to or greater than 3 mm,
in an easily accessible position close to the appliance.
If a plug and socket connection is being used make sure that the plug and
socket are compatible. Avoid use of adapters and shunts as these could
cause overheating and burns.
Operation at 220-240 V~: use
an H05RR-F type three-core
cable (3 x 1.5 mm
2
).
The end to be connected to the
appliance must be an earth wire
(yellow-green) at least 20 mm
longer.
13.2 Positioning the oven
The oven is designed for mounting into any piece of furniture as long as it
is heat-resistant. Proceed according to the dimensions shown in Figures
1, 2 and 3. For installing under a work top, follow the dimensions given in
Figure 1-3. For installing under a work top with combined cooking hobs,
ensure a minimum clearance from any side walls of at least 110 mm as
shown in Figure 1. When installing in tall units, comply with the dimensions
shown in figure 1-2, bearing in mind that the top/rear of the unit must have
an opening 80-90 mm deep. Tighten the 4 screws A inside the frame (fig.
1). For installing beneath a countertop hob, allow for a rear and bottom
clearance as shown in Figure 1 (ref. B). See the relevant instructions for
fitting and securing the hob.