Smeg SCP107AL Microwave Oven User Manual


 
53
Instructions for the User
10.6.3 Setting the cleaning cycle
Use PT2 to select one of the two pyrolysis functions ( and ) with the
oven in OFF status (see point 7.4, Function Selection).
To start the cleaning (Pyrolysis) cycle, press knob PT1 once to set its
duration ( ).
Turn knob PT1 to the right or left to increase or decrease the cycle
duration between a minimum of 1h 30m and a maximum of 3h 00m
(except for the function where the cycle duration is fixed at 1h 30m).
The message PYro will appear on DSP1 to indicate that the oven is
performing the cleaning cycle (for the
function, DSP1 shows Peco).
One minute after the cleaning (Pyrolysis) cycle starts an interlock device
which prevents opening of the door will be tripped.
The symbol illuminates on DSP1 to indicate that this interlock device
has been activated.
To select a cleaning cycle with delayed start, after setting the duration
press PT1 once. The symbol and the current time will appear on the
display.
Turning PT1 to the right increases the time, allowing the cleaning start
time required to be set.
A few seconds after the required duration is set, the and symbols
will stop flashing, and the oven will start to wait for the starting time set.
It is not possible to select any functions once the door interlock has been
activated. Wait for the symbol to go out.