Smeg SE2631ID1 Cooktop User Manual


 
Instructions for the installer
28
For operation on 380-415 V 3N
: use an H05V2V2-F - type five-core
cable (5 x 1.5 mm
2
) heat-resistant to at least 90°C.
For operation on 380-415V 2N
: use an H05V2V2-F - type four-core
2
) heat-resistant to at least 90°C. cable (4 x 1.5 mm
For operation on 220-240 V 3
: use an H05V2V2-F - type four-core
2
) heat-resistant to at least 90°C. cable (4 x 1.5 mm
For operation on 220-240V
:
30 cm hobs: use an H05V2V2-F type three-core cable, heat-resistant to
at least 90°C.
(cable 3 x 1.5 mm
2
)
60-70 cm hobs: use an H05V2V2-F type three-core cable, heat-
resistant to at least 90°C.
(cable 3 x 4 mm
2
)
90 cm hobs use an H05V2V2-F type three-core cable, heat-resistant to
at least 90°C.
(cable 3 x 6 mm
2
)
The earth wire (yellow-green) must be at least 20 mm longer than the
other wires at the end for connection to the appliance.
Depending on the hob you have purchased, the possible electrical connections are:
30 cm hobs: 220-240V
60-70 cm hobs: 220-240V
/ 220-240V 3
/ 380-415V 2N
90 cm hobs: 220-240V
/ 220-240V 3
/ 380-415V 2N
/ 380-415V 3N
READ THE CONNECTION LAYOUT PLATE UNDERNEATH THE APPLIANCE OR AROUND THE
POWER CABLE WITH CARE.
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions or by interference with any part of the appliance.