Smeg SER63LPG3 Cooktop User Manual


 
Instructions for the installer
11
5 ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the
appliance from the electrical socket.
The hob has been inspected for LPG at a pressure of 30 mbar.
5.1 Removing the separable control panel (models with
separable control panel)
1. Remove the knobs and the knob
guard tube “A” by pulling them up;
2. Use a crosshead screwdriver to
remove the screws and the two
cylindrical supports “B”;
3. Raise the left-hand side of the
control panel slightly and shift it to
the right to remove it completely;
4. In models with electric hotplate, the
body of the pilot light has to be
removed to free the control panel;
5.2 Removing the hob (models with integrated control
panel)
1. Remove the knobs, the
griddles, the burner caps, the
flame caps and the two rear
plugs;
2. Remove the screws “A
which fix the burner supports;
3. Raise the hob, sliding it off
the ignition plugs and/or the
thermocouples and the gas
tap rods;