Instructions for the installer
4. FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the
burner caps and the grids.
4.1 Adjustment of the hob burner minimum level for natural gas
Light the burner and take it to the minimum .
Remove the gas tap knob and turn the
adjustment screw inside of the tap shaft
(depending on the model) until there is a regular
minimum flame. Replace the knob and check
burner flame stability: (rapidly turning the knob
from maximum to minimum position, the flame
should not go out). Repeat the operation on all
the gas taps.
4.2 Adjustment of the hob burner minimum level for LPG
(propane)
To regulate the minimum for LPG (propane), completely tighten
(clockwise) the screw inside or next to the gas tap pin (depending on the
model).
4.3 Arrangement of the burners on the hob
Burners
1 Auxiliary
2 Semi rapid
4 Wok
12