Smeg SUK81MFX5 Range User Manual


 
Instructions for the installer
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.0 50 30 350 73 71
Semi rapid 1.75 65 33 450 127 125
Rapid 2.3 75 45 800 167 164
Triple crown 3.5 94 65 1500 254 250
Oven 3.2 87 48 850 233 229
Maxi oven 4.6 106 59 1200 378 371
Grill 3.7 95 // // 268 264
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.0 72 350
Semi rapid 1.75 97 450
Rapid 2.3 103 800
Triple crown 3.5 140 1500
Oven 3.2 130 850
Maxi oven 4.6 155 1200
Grill 3.7 145 //
3.3 Arrangement of the burners on the hob
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Triple crown
9