1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
www.yatesgd.com www.yatesgraphicdesign.com
348EE-2G 348EE-2T
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
Dimensions -in (mm)
Form 348EE-2G/T Rev 1 (04/07)
MISCELLANEOUSUTILITY INFORMATION
OPTIONS AND ACCESSORIES
10” Flue Riser
3/4” quick disconnect with flexible hose complies with
ANSI Z 21.69 (specify 3ft, 4ft, 5ft)
Casters-all swivel-front with locks
Hot Top plates - each plate replaces 2 Open burner section
Various salamander & cheesemelter mounts
available. (Please refer to the price list)
Auxillary griddle plates
Extra Oven Racks
Stainless steel body sides
MODELS
EXTERIOR
COOK
TOP
DOOR
OPENING
OVEN
BOTTOM
3/4" GAS CONN.ELECTRIC
Wid th
A
Depth
B
CDEFGHJKLMNOPQR
348EE-2G/2T
48.63"
(1235)
34.00"
(864)
29.75"
(756)
31.00"
(787)
12.00"
(305)
2.75"
(70)
59.50"
(1511)
22.50"
(572)
31.00"
(787)
6.00"
(152)
37.00"
(940)
15.50"
(394)
13.00"
(330)
3.25"
(83)
30.25"
(768)
--
Models
B
URNERS (BTU EACH NAT/LP) OVEN INTERIOR CRATE SIZE
CUBIC
VOLU ME
CRATED
WEIGHT
GRIDDLE OPEN OVEN WIDTH DEPTH HEIGHT WIDTH DEPTH HEIGHT
348EE-2G/2T 3@(16K/16K) 8@(26K/20K) 2@(32K/30K)
19.50"
(495)
26.50"
(673)
14.00"
(356)
67.00"
(1702)
45.50"
(1158)
75.00"
(1905)
132.3 cu. ft
3.75 cu.m.
860 lbs.
390 kg.
-If using Flex-Hose, the I.D. should not be smaller than 3/4”
and must comply with ANSI Z 21.69
-If casters are used with flex hose, a restraining device should
be used to eliminate undue strain on the flex hose
-For installation on combustible floors (with 6” high legs) and
adjacent to combustible walls, allow 6” clearance.
-Install under vented hood
-Check local codes for fire, installation and sanitary
regulations.
NOTICE:
Southbend has a policy of continuous product research and
improvement. We reserve the right to change
specifications and product design without notice. Such
revisions do not entitle the buyer to corresponding
changes, improvements, additions or replacements for
previously purchased equipment.
Model: 348EE-2G/T
Gas:
- 348EE-2G/2T Total BTU-NAT:320,000; LP: 268,000
- One 3/4” male connection
- Required operating pressure:
Natural Gas 4” W.C.
Propane Gas 10” W.C.
- If using Flex-Hose, the I.D. should not be smaller than the I.D. of
the manifold of the unit to which it is being connected
- Check local codes for fire and sanitary regulations.
- If the unit is connected directly to the outside flue, and A.G.A
approved down draft diverter must be installed at the flue outlet
of the oven
-Two speed motors are not available on Restaurant Range
Convection Ovens.
NOTES:
1. Optional -Hot Plate in lieu of 2
open top burners at 12,000 BTU/
burner (24,000 BTU total NAT or LP
2. T Prefix - Thermostat griddle
control with one (1) throttling-type
thermostat per burner. Temperature
range of 100
o
F to 450
o
F)