Southbend 360AA-2GL Range User Manual


 
OPERATION MODEL 300 RESTAURANT RANGES
OPERATION
! DANGER
EXPLOSION HAZARD
In the event a gas odor is detected, shut down equipment at the main shut off valve. Immediately call
the emergency phone number of your gas supplier.
! CAUTION
To eliminate gas build up which could result in an explosion, in the event of main burner ignition
failure a five minute purge period must be observed prior to re-establishing ignition source.
OPERATION
! CAUTION
Top section pilots, when out, do not interrupt the flow of gas to the burners. Consequently, it is the
responsibility of the operator to check the ignition of the burners, immediately after burner value has
been turned “ON”. Should ignition fail after 10 seconds, turn off burners, wait 5 minutes, and then try
again.
LIGHTING AFTER GAS HAS BEEN SHUT OFF
When turning the main gas supply on after the gas supply has been shut off, do the following:
1. Make sure all of the control valves are in the “OFF” position.
2. Turn on the gas supply.
3. Light the pilots as described below.
4. Light oven first and then wait six minutes before lighting top section. This allows all air to be purged from
the range.
OPEN-TOP BURNER SECTIONS
Each open-top burner is controlled by a knob on the front control panel.
To light the pilots of an open-top burner section, do the following:
1. Turn all gas valves to the “OFF” position.
2. Check to make sure pilots are in the correct position.
3. Light the pilots.
4. Adjust the pilot flame as necessary.
PAGE 16 OPERATORS MANUAL 1182298 REV 3