Southbend 45lb Fryer User Manual


 
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
www.yatesgd.com www.yatesgraphicdesign.com
6" (152)
30"
(762)
ModelP16-PF45 ModelP20-PF65
60"
(1524)
72"
(1829)
24"FlueRiser
36"FlueRiser
36"
(914)
33-34"
(859)
4-1/2" (114)
37-3/4" (960)
34" (864)
40" (1017)
43-3/4" (1112)
Flueriserforìdeepîdepth-option
extends rearward 6" (frypot size
is the same as for standard depth).
FrontGas
Manifold
ModelP16-PF45 ModelP20-PF65
16"
(406)
20"
(508)
33-3/4"
(858)
9"
9"
(178)
2-3/4 "
(70)
(178)
5-1/2"
(140)
2-3/4"
(70)
Optional rear gas connection,
for non-battery installations
P16-PF45 P20-PF65
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
.
OPTIONS AND ACCESSORIES
GAS: Each unit has a 1-1/4” front gas manifold that couples to the
adjacent sectional unit(s), and a 1” rear gas connection with a male
NPT connector. Minimum supply pressure is 7” W.C. for natural gas
and11”W.C.forpropane.Allsectionalunitsrequirearegulated
gas supply; pressure regulator to be ordered separately. If using a
exiblehosegasconnection,theI.D.ofthehosemustnotbesmaller
than the connector on the unit and must comply with ANSI Z21.69,
providinganadequatemeansofrestrainttopreventunduestrainon
the gas connection
MISCELLANEOUS
UTILITY INFORMATION
-Ifcastersareusedwithexhose,arestrainingdevice
shouldbeusedtoeliminateunduestainontheexhose.
- Minimum clearance from noncombustible construction
is zero. Minimum clearance from combustible construc-
tion is 10” on sides and 6” on rear.
- Install under vented hood.
-Checklocalcodesforreandsanitaryregulations.
NOTICE:
Southbend has a policy of continuous product research
and improvement. We reserve the right to change
specicationsandproductdesignwithoutnotice.Such
revisions do not entitle the buyer to corresponding
changes, improvements, additions or replacements for
previouslypurchasedequipment.
FormPSFRev1(06/07)

Fryerltersystem
 Stainless steel frypot cover
 Extra single basket (full size) for 14” pot
 FlueRisers:24”,36”
 Heat lamp over drain cabinet
 Cable restraint kit
 Extra twin size basket for 14” pot
 Stainless steel sides
 Stainless steel divider
SHIPPING CRATE DIMENSIONS & WEIGHT
(Door-entry clearance when uncrated is 16.5” for
Model P16-PF45 and 20.5” for Model P20-PF65)
Model Width Height Depth Volume Weight
P16-PF45
20.0
(508)
45.0
(1143)
42.5
(1080)
22.1 cu ft
(0.63 cu m)
210 lbs
(95 kg)
P20-PF65
23.0
(584)
41.0
(1041)
43.0
(1092)
23.5 cu ft
(0.66 cu m)
265 lbs
(120 kg)
GAS
Model
Natural/Propane
BTU/Hour
P16-PF45 110,000
P20-PF65 150,000